GW-5250
Thermally improved impact-rated window wall; Miami-Dade certified, LMI + SMI, DP +130/-130 psf, 2.5" sightline, dual finish capability.
NOAs, Florida Product Approvals, cut sheets, CSI 3-part specs, and installation guides for every system ACG is authorized to install. Verified direct links. No forms. No gatekeeping.
Specification documents are organized by manufacturer and system. Every link opens the verified-current PDF directly from the manufacturer's server — no forms, no login walls, no stale reprints.
For CAD details, Revit families, or specific test reports not listed, contact Connor direct. Most manufacturer CAD packages are login-gated and ACG can pull them for an active project in under a business day.
ACG is an authorized ESWindows installer for Florida. Commercial storefront, impact storefront, window wall, and door systems — engineered, NOA-approved, and installed under a single subcontract. Verified direct links to every currently-available document below.
Thermally improved impact-rated window wall; Miami-Dade certified, LMI + SMI, DP +130/-130 psf, 2.5" sightline, dual finish capability.
Pre-assembled, pre-glazed window wall system; ES-7000 = LMI, ES-7100 = SMI; 6-1/8" frame depth, flush glazed, DP +125/-150 psf, screw spline construction, compatible with ES-9000 door.
Impact-resistant storefront system; pre-assembled with screw spline construction, pre-glazed; LMI rated; 5" frame depth, 1.75" + 1" recessed fin sight line; 9/16" laminated glass; DP +80/-130 psf; compatible with ES-9000 door. Also available as ES-8000T (thermally broken pour-and-debridge).
Impact-rated commercial entry door; outswing and inswing configurations; LMI + SMI rated; DP +130/-130 psf (single); compatible with ES-8000 storefront and ES-7000 window wall; pre-assembled door leaf; ADA threshold option.
ACG is an authorized Euro-Wall Florida dealer. Folding walls, multi-slide, pivot, lift-and-slide, casement, and fixed window systems — manufactured in North Port, Florida. Full document library with direct cut sheets, install guides, CSI specs, and Florida Product Approvals.
Impact-rated aluminum folding door; HVHZ approved (Miami-Dade); panels up to 144" tall, 53" wide; DP up to 100 psf; LMI + SMI; ADA sill option; 10-year warranty; Florida Product Approval FL 27023.
Thermally broken aluminum folding door; impact and non-impact rated; larger panel sizes than standard C3 (up to 168" tall, 52" wide); DP up to 100 psf; LMI rated; Florida Product Approval included.
Impact-rated multi-slide door; thinnest interlock profile on market (<1" sight line); panels up to 70 sq ft (144" tall × 96" wide); DP up to 70 psf; HVHZ approved; flush embedded water-rated sill; no sill riser; Florida Product Approval FL 27423.
Impact and non-impact rated pivot door; heights up to 14' (168"), widths up to 100"; aluminum, interior wood clad, or faux wood grain kynar finish; designed for commercial and residential applications.
Euro-Wall lift-and-tilt sliding door system; commercial and residential applications; impact and non-impact rated configurations.
Casement and tilt-turn window system; impact and non-impact rated; designed to complement Euro-Wall door systems.
Impact-rated fixed window / direct-set glazing system; HVHZ approved; Florida Product Approval FL 46965; panels from 18" to 108" wide, 18" to 168" tall; complements all Euro-Wall door systems.
Some documents — particularly FL Product Approvals and historical Miami-Dade NOAs — are hosted only on state portals. These are the direct entry points.
Per-square-foot budget ranges for system selection before CDs. ACG provides ranges based on actual Florida pricing, not national averages.
Confirm ESWindows or Euro-Wall system fit for your specific project exposure, height, wind load, and code requirements before spec release.
Shop-drawing-ready CAD details and Revit families available from ACG for active projects. Faster than pulling from manufacturer login-gated portals.
AAMA 501.1 dynamic water and thermal testing coordinated at approved Florida labs. Mock-up details specified in shop-drawing phase.
ACG delivers HSW-approved continuing education on Florida Division 08 best practices. Scheduled on request at your office.
Pre-submittal review of proposed manufacturer packages. ACG flags NOA gaps, DP mismatches, and coordination conflicts before GC submits.
Connor Walsh, President and CGC #1531993 qualifier. 48-hour response on specification requests. Skip the distributor. Go direct.